CW-5000DG industrial water chillers have been popular for over 16 years with the annual output of 30,000 units.It is designed for cooling the one CO2 glass laser tube under 120W of the laser engraving and cutting machine. (Its emitting rate is higher than 60%.)
Cooling capacity is 800W.
Have design patent Certificate, CE and RoHS Certificate.
This Water Chiller has been sold largely to Europe, South America, Asia and other markets.
Economic cooling equipment, easy to install and operate, compact and easily movable.





The new T503 intelligent temperature controller does not need to adjust the controlling parameters under normal circumstance. It will self-adjust controlling parameters according to room temperature for meeting equipment cooling requirements.
User also can adjust the water temperature as needed.
Temperature controller panel description:
In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5000/5200series chillers possesses an unique low flow alarm protection.
Note: The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.


Chiller CW-5000 for 120W metal laser cutting machine
Water chiller CW-5000 for acrylic co2 laser cutting machine
Industrial chiller CW-5000 for laser cutter
Air cooled chiller CW-5000 for co2 laser cutting & engraving machine
Water cooled chiller CW-5000 for uv laser marking machine
CW-5000 chiller for 3w-5w uv laser machine
Refrigeration water chiller CW-5000 for laser marking machine
Compressor water chiller CW-5000 for UV curing system printer
Industrial water chiller CW-5000 for laser marker





Open the package to check if the machine is intact and all the necessary accessories are completed. |
Open the injection port to feed cooling water. (Do not let the water spill over!) |
According to system conditions, please connect the water inlet and outlet pipe well. |
Plug in power, turn on the power switch. (Do not start up without water in the water tank!)(2) After the first boot, you must immediately check whether the water pipe leaks. (3) Power switched on, if the water temperature is below the set value, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters. (4) As it takes a longer time to start over the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently. |
Check the water level in the water tank. |
Adjust parameters of temperature controller. |
Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded! |
Please make sure there is stable and normal voltage for the working chiller! |
Unmatched power frequency can cause the chiller damage! |
To protect the pump, it’s strictly forbidden to run the chiller without water in the storage water tank! |
Please be sure that the air inlet and air outlet are in good ventilation! |
The filter screen must be regularly cleaned! |
Please pay attention to the effect of the condensate water! |
Professional use only!
|
| Failure | Failure Cause | Approach |
|---|---|---|
| Machine turned on but unelectrified | ||
| Power cord is not plugged in place | Check and ensure the power interface and the power plug is plugged in place and in good contact. | |
| Fuse burnt-out | Pull out the fuse box from the power supply interface of the chiller, check the fuse, replace with spare fuse if necessary and check whether the power supply voltage is stable; Check and ensure the power interface and the power plug is plugged in place and in good contact. | |
| Flow Alarm (panel red light is on)use a water pipe directly connect to the water outlet and inlet but still without water flowing | Water level in the storage water tank is too low | Check the water level gauge display, add water until the level shown in the green area; And check whether water circulation pipe leaks. |
| Flow Alarm occurs while running with other equipment (panel red light is on),but there is water flowing and no alarm when use a water pipe directly connected to the chiller water outlet and inlet. | Water circulation pipes are blocked or a pipe bending deformation. | Check water circulation pipe |
| Ultra-high temperature alarm | ||
| Blocked dust gauze, bad thermolysis | Unpick and wash the dust gauze regularly | |
| Poor ventilation for air outlet and inlet | To ensure a smooth ventilation for air outlet and inlet | |
| Voltage is extremely low or astable | To improve the power supply circuit or use a voltage regulator | |
| Improper parameter settings on thermostat | To reset controlling parameters or restore factory settings | |
| Switch the power frequently | To ensure there is sufficient time for refrigeration (more than 5 minuets) | |
| Excessive heat load | Reduce the heat load or use other model with larger cooling capacity | |
| Alarm for ultra-high room temperature | The working ambient temperature is too high for the chiller | To improve the ventilation to guarantee that the machine is running under 40℃. |
| Serious problem of condensate water | Water temperature is much lower than ambient temperature, with high humidity | Increase water temperature or to preserve heat for pipeline |
| Water drains slowly from outfall during water changing | Injection port is not open | Open the injection port |